Multiply the energy used in kWh by your unit rate in pence, then divide by 100. Use this tool for a plug-in monitor reading or the difference between two electricity meter readings. You do not need to convert measured energy into watts or multiply it by hours again.
Enter your measured use
Calculations stay in this page. Nothing is sent to a server or stored. Enter energy used during the period, not the meter’s lifetime total.
Use pence: enter 26.32 for 26.32p, not 0.2632. A fixed negative rate is accepted; changing or time-of-use rates need separate calculations for each rate period.
Electricity cost for this period:
Energy used:
Average cost per day:
Standing charges are excluded. This is a constant-rate illustration, not a bill forecast.
Which reading should I enter?
If your monitor started at zero, enter its accumulated kWh for the period. Otherwise subtract the starting reading from the ending reading. For example, a meter moving from 1,204.6 to 1,208.1kWh recorded 3.5kWh of use. Do not enter the entire ending register value as consumption.
Use readings from the same electricity register and note any resets. A whole-home meter includes all household loads; its difference cannot identify which appliance used the energy. This tool is for electricity kWh, not a gas meter’s volume reading.
Example: seven days of use
At a teaching rate of 25p/kWh, 3.5kWh costs £0.875, or about 88p. Over seven days, the average is 12.5p per day. The calculator retains extra decimal places so small costs remain visible. A supplier’s rounding may differ.
The number of days changes the daily average, not the cost of the energy you already measured. For a 12-hour observation, enter 0.5 days. A short observation may not represent a full day’s normal use, especially for equipment that cycles or runs infrequently.
What is excluded?
Standing charges are excluded. For a whole-bill estimate, add the relevant daily standing charges separately or use the bill estimator. Enter your actual unit rate, including any tax already applied on your bill; the tool does not add tax again.
The calculator applies one rate to all entered energy. If the price changed during the period, calculate the energy used at each rate separately and add the costs. Do not use a simple average price unless equal amounts of energy were consumed at each price. Zero and fixed negative rates are accepted; export credits and tariff-specific rewards are not modelled.
Use the result
Keep the measurement dates, settings and conditions alongside the reading. Compare equivalent tasks before attributing a difference to an efficiency improvement. Our seven-day audit provides a recording sheet; the measurement guide explains how to obtain a useful reading safely.